EN ISO 17635: which inspection method for which weld?
It is the question we are asked most often, and almost nobody answers it properly. The answer sits in a chain of five standards. Here it is, in order.
A client calls: "I need some testing on welds, what do you do?" The right answer is never "ultrasonics" or "a radiograph". It starts with a question back: what does your specification require?
Because the choice of method is not a matter of taste, and certainly not a matter of what the contractor happens to have in the van. It follows from a logical chain that EN ISO 17635 organises. Once you have that chain, half the misunderstandings disappear — and the other half are settled with three questions to the client.
What ISO 17635 actually does
It does not say "for a butt weld, use ultrasonics". It gives the general rules for choosing the method and the acceptance criteria, from five inputs:
- the quality level required for the weld;
- the material — ferritic and austenitic steels are not inspected the same way;
- the thickness of the weld;
- the welding process;
- the extent of testing, partial or full.
Give it those five and it points you to the relevant method or methods, then to the technique standard to apply and to the matching acceptance-level standard.
The current edition is the fourth, published April 2025. If your specification still refers to the 2016 edition, that is not necessarily a problem — a contract may legitimately freeze an edition — but it is worth raising before work starts rather than after.
The full chain, in order
This is the part almost no commercial documentation explains, and it is the part that prevents end-of-job disputes. Five links:
1. The quality level of the weld. Set by EN ISO 5817, which defines three levels — B, C and D, B being the most stringent. That level is not chosen at inspection: it is fixed upstream by the construction code or the specification. It is a fabrication requirement.
2. Naming the imperfection. EN ISO 6520-1 classifies and numbers every type of imperfection. It is the common vocabulary: when a report says 401, everyone knows it is a lack of fusion, whatever language the document is in.
3. Choosing the method. That is ISO 17635, from the five inputs above.
4. The technique. One standard per method, setting out how the inspection is physically carried out: EN ISO 17637 for visual testing, EN ISO 3452-1 for penetrant, EN ISO 17638 for magnetic particle, EN ISO 17640 for ultrasonics, EN ISO 17636-1 and -2 for radiography, on film or with a digital detector.
5. The acceptance levels. Again one standard per method: EN ISO 23277 for penetrant, EN ISO 23278 for magnetic particle, EN ISO 11666 for ultrasonics, EN ISO 10675-1 for radiography. There, and only there, is the answer to "is this indication acceptable?".
Skip a link and disagreement is guaranteed. The classic case: a report concluding "compliant" without saying against which acceptance level, on a job where the client expected the most stringent one.
The trap almost everyone misses
The quality levels of ISO 5817 (B, C, D) and the acceptance levels of the testing standards are not the same thing, and they do not translate directly into one another.
That is counter-intuitive, so here it is another way. ISO 5817 describes what a weld is allowed to contain — a requirement on the product. The acceptance standards describe what an inspection may detect and declare acceptable — which also depends on the sensitivity of the method and on what it is physically capable of seeing. No method sees everything, and two methods do not see the same defects.
In practice: asking an inspector for "level B", with nothing else, is not a complete instruction. You need the quality level and the acceptance level, or failing that the product standard that imposes both.
A second and quieter subtlety: acceptance standards refer to whichever edition of ISO 5817 was current when they themselves were published. EN ISO 11666, issued in 2018, therefore refers to ISO 5817:2014 — while ISO 5817 is now at its 2023 edition. That lag is normal within a body of standards and is resolved by the project specification, but you would rather spot it than have an auditor spot it.
What the material changes
Material is not an administrative detail in this chain. It is an input that can rule a method out.
Austenitic steels — typically the 300-series stainless grades — are difficult with conventional ultrasonics: the structure of the weld metal scatters and attenuates the beam, degrading detection and complicating interpretation. Dedicated standards and techniques exist, but that is specialist work, not a menu option.
Magnetic particle testing applies only to ferromagnetic materials. On an austenitic it does not work: that is physics, not regulation. Penetrant testing then takes over for surface-breaking defects.
Thickness closes other doors. Below a certain thickness ultrasonics on a weld becomes impractical and radiography regains the advantage. Above it, the balance tends to reverse, for reasons of exposure time and radiation safety.
Which is why a serious answer to "what testing do I need?" starts with questions rather than a quotation.
Radiography and ultrasonics do not see the same things
A persistent belief holds that radiography is "the most complete inspection". It is not, and the distinction has direct consequences.
Radiography sees volume very well: porosity, slag inclusions, lack of penetration. It sees poorly anything that is planar and badly oriented relative to the beam — and sidewall lack of fusion, or a fine crack, are exactly that. On a film, lack of fusion only reads if the shooting angle is favourable.
Ultrasonics is strong precisely where radiography is weak: planar defects reflect the beam. In exchange it lends itself less well to finely characterising scattered porosity, and it leaves no image to be pulled out of a file ten years later, which matters in some sectors.
Hence a practical consequence clients sometimes discover late: on a critical joint, combining two methods is not commercial enthusiasm. It is often what the product standard requires, precisely because no single method covers the whole range of defects.
Three questions for your client
If you take one thing from this article: before requesting an inspection, get these three answers. They are enough to scope any job.
- Which product standard applies? EN 1090 for structural steelwork, EN 13445 for pressure vessels, EN 13480 for industrial piping, a client code, a project specification. It drives everything else.
- Which quality level, and which acceptance level? Both, not one of the two.
- What extent of testing? A percentage of joints, a named list, all of them. And on what basis that percentage was set.
If your contact cannot answer, that is fine — it is in fact common. Call us: working back up the chain from the product standard is part of the job, and it usually takes one phone call.
Standards cited in this article
-
EN ISO 17635:2025— Non-destructive testing of welds — General rules for metallic materials -
EN ISO 5817:2023— Welding — Fusion-welded joints in steel, nickel, titanium and their alloys — Quality levels for imperfections -
EN ISO 6520-1:2007— Classification of geometric imperfections in metallic materials — Part 1: fusion welding -
EN ISO 10675-1:2021— Acceptance levels for radiographic testing — Part 1: steel, nickel, titanium and their alloys -
EN ISO 11666:2018— Ultrasonic testing — Acceptance levels -
EN ISO 23277:2015— Penetrant testing of welds — Acceptance levels -
EN ISO 23278:2015— Magnetic particle testing of welds — Acceptance levels
The editions given are those verified with the issuing body at the time of writing. Standards are copyright works: we reproduce neither their text nor their tables. They are available from NBN or from your national standards body.